All of a sudden two problems and printer is down. Started with a wind error didn't want to clear so powered off printer rebooted computer. Then SCSI not recognized. Playing around with that checking connections looking for error messages etc. and now capping station will not move up or down. Had to manually close to keep heads moist. I was in secret maintainence menu looking around and am not sure if mabe I reset something that is easily fixable or if I have mechanical problems...Help!!?
as I replyed to you in PM, I'll also post short conclusion here:
1. winding error comes from winding sensor - if sensor is blocked (material places between sensor and reflection plate), than winding motor starts to wind material. if in some time this material doesn't wind and in that way unblock sensor, than you receive that error. so, check if this winding "circle" is ok (sensor, reflection plate, cables...)
2. in process of booting PC, when you want SCSI card (on PC) to recognise printer, printar HAS to be in ready/online status. if it is not, there is small possibility that SCSI will see printer
3. capping station is moved by motor in side of it. if this motor is ok than you might have problem with one of gears that are connected to long shaft (which is turning pumps).
-- Edited by cs6060 on Wednesday 13th of June 2012 05:50:36 AM